{"product_id":"soundetix","title":"Soundetix","description":"\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMonitor Sound Levels And Environmental Conditions Simultaneously With The Professional Soundetix Sound Level Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003e30 to 130 dBA measurement range with ±1.5 dB accuracy, A and C frequency weighting, 125ms FAST and 1-second SLOW response modes, simultaneous temperature, humidity, wet-bulb, and dew point monitoring, large backlit LCD display, MAX\/MIN recording with data hold, high-response condenser microphone with protective wind and dust cover, compact 115.7g design, and auto power-off after 10 minutes — the Soundetix delivers comprehensive environmental monitoring for construction, industrial, and residential noise assessment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eLooking For A Sound Meter That Also Monitors Temperature And Humidity Simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe Soundetix goes far beyond single-function sound measurement by simultaneously displaying temperature, relative humidity, wet-bulb temperature, and dew point alongside sound level readings — providing the complete environmental picture that noise assessment professionals, HVAC engineers, and industrial hygienists need without carrying multiple separate instruments to each measurement location.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eNeed A Sound Level Meter With Both A And C Frequency Weighting For Different Applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe HT602B model provides both A-weighting for human hearing-matched environmental noise assessment and C-weighting for low-frequency machine noise and industrial equipment evaluation — covering the two most commonly required regulatory measurement standards in a single instrument that adapts to different professional noise assessment requirements with a simple weighting selection.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFrustrated By Displays That Are Difficult To Read In Dark Industrial Environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe large backlit LCD maintains clear readability in poorly lit construction sites, basement mechanical rooms, factory floors, and any low-light measurement environment where standard displays become difficult to read — combined with the MAX\/MIN recording and data hold functions that freeze readings for comfortable documentation without maintaining continuous visual contact with the display.\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e30 To 130 dBA Range With ±1.5 dB Accuracy And A\/C Frequency Weighting Options\u003c\/li\u003e\n\u003cli\u003eSimultaneous Temperature, Humidity, Wet-Bulb, And Dew Point Environmental Monitoring\u003c\/li\u003e\n\u003cli\u003e125ms FAST And 1-Second SLOW Response Modes For All Noise Assessment Types\u003c\/li\u003e\n\u003cli\u003eMAX\/MIN Recording And Data Hold With Large Backlit LCD For Clear Dark Environment Reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWHY CHOOSE SOUNDETIX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWIDE 30-130 dBA MEASUREMENT RANGE\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eCoverage from quiet 30 dBA ambient environments through to dangerously loud 130 dBA industrial noise encompasses the complete spectrum encountered across construction sites, workshops, residential neighbourhoods, automotive environments, and agricultural settings without range-switching limitations during comprehensive site surveys.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eA AND C FREQUENCY WEIGHTING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA-weighting matches the frequency response of human hearing for environmental noise and occupational health assessment, while C-weighting captures low-frequency machine noise and industrial equipment output that A-weighting underestimates — both standards available in a single instrument covering all professional regulatory measurement requirements.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMULTI-PARAMETER ENVIRONMENTAL MONITORING\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eSimultaneous sound level, temperature, humidity, wet-bulb temperature, and dew point measurement provides the complete environmental data set needed for comprehensive workplace assessment, HVAC performance evaluation, and industrial hygiene documentation without multiple separate instruments at each measurement point.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFAST AND SLOW RESPONSE MODES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eFAST mode at 125 milliseconds captures transient noise events, impact sounds, and sudden machinery starts that disappear before slower meters register them, while SLOW mode at 1 second averages fluctuating stable noise for representative background level assessment — the right response time for every measurement scenario.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCONDENSER MICROPHONE PRECISION\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe high-response condenser microphone with protective wind and dust cover provides accurate sound capture across the full measurement range while the physical protection maintains microphone performance during outdoor field use and dusty industrial environments where unprotected microphones degrade rapidly.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCOMPACT PROFESSIONAL DESIGN\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eAt 142x58x28mm and 115.7g the Soundetix fits in any tool bag, lab coat pocket, or equipment case for effortless field transport — AAA battery operation with 10-minute auto shutdown conserves power during site surveys where convenient charging is unavailable between measurement sessions.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMEET THE SOUNDETIX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat is the difference between A-weighting and C-weighting measurements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eA-weighting filters the measurement to reflect the frequency sensitivity of human hearing, de-emphasising very low and very high frequencies — the standard for environmental noise regulations, occupational health assessments, and residential noise complaints. C-weighting applies a flatter response that captures low-frequency machine noise more accurately, used for industrial equipment assessment and situations where low-frequency content is significant.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhen should I use FAST mode versus SLOW mode?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eUse FAST mode at 125 milliseconds for capturing sudden noise events, impact sounds, machinery start-up noise, and transient sounds that disappear before slower meters register them. Use SLOW mode at 1 second for stable background noise assessment, HVAC system evaluation, and ambient environment monitoring where instantaneous peaks are less relevant than the overall sustained noise level.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow does the wet-bulb and dew point measurement benefit noise assessment professionals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWet-bulb temperature and dew point data help assess condensation risk on sensitive measurement equipment, evaluate HVAC system performance alongside noise output, and provide the complete environmental context required for industrial hygiene reports that must document both acoustic and environmental conditions at each measurement location.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat applications is the C-weighting mode specifically suited for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eC-weighting is used for low-frequency machine noise assessment, industrial equipment evaluation, hearing protection calculations where low-frequency content affects protection requirements, and regulatory measurements that specifically require dBC rather than dBA readings — particularly relevant in manufacturing, automotive workshops, and heavy industrial environments.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow accurate is the ±1.5 dB specification at other sound levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe ±1.5 dB accuracy is specified at the reference condition of 94 dB at 1 kHz — a standard calibration reference point. Accuracy across the full 30 to 130 dBA range may vary slightly from this reference specification. For formal regulatory compliance measurements requiring traceable calibration documentation consult local standards for required instrument accuracy grades.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDoes the auto power-off affect stored MAX\/MIN values?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe 10-minute auto power-off activates after inactivity to conserve battery life. Refer to the included user manual for specific data retention behaviour after auto shutdown — most instruments of this type clear working memory when powered off, so record or note MAX\/MIN values before the device shuts down during extended measurement breaks.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCan it be used for formal occupational noise exposure assessments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe ±1.5 dB accuracy and A\/C weighting capability provide measurement reliability suitable for preliminary occupational noise screening and site assessments. For formal regulatory compliance documentation and legal noise exposure records, consult local occupational health standards regarding required instrument type, accuracy grade, and calibration certification requirements.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eWhat maintenance does the condenser microphone require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eKeep the protective wind and dust cover fitted whenever the meter is not actively measuring to protect the condenser capsule from dust, moisture, and physical damage. Inspect the cover periodically for blockage that could affect frequency response and replace if damaged — a clean, undamaged microphone capsule is the primary factor in maintaining measurement accuracy over extended regular use\u003c\/p\u003e","brand":"LyonMax","offers":[{"title":"HT602A","offer_id":53873587126555,"sku":"HG01714310","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/4775\/6571\/files\/soundetix-img-16.png?v=1788492122","url":"https:\/\/www.lyonmax.com\/products\/soundetix","provider":"LyonMax","version":"1.0","type":"link"}